Description
Description
Having the right tool for the job is essential. Having all the right tools when you need them is even better.
The Fluke 116/323 HVAC Combo Kit gives you the best in a versatile, rugged multimeter and a fast-acting, general purpose clamp meter.
Together, the Fluke 116 HVAC Multimeter and 62 MAX+ Infrared Thermometer give HVAC technicians the right tools for the job.
Fluke 116 HVAC Multimeter
The Fluke 116 comes with the Fluke 80BK-A integrated DMM temperature probe.
The microamp function allows flame sensor measurement down to 0.1 microamps.
The AutoV/LoZ function prevents false readings caused by ghost voltage.
The Fluke 116 also has a large white LED backlight for work in poorly lit areas.
It measures resistance, continuity, frequency, and capacitance and provides Min/Max/Average
readings with elapsed time to record signal fluctuations.
Fluke 116 multimeters are independently tested for safe use in CAT III 600V environments.
Built-in thermometer for HVAC applications
Microamps to test flame sensors
Low input impedance helps prevent false readings due to ghost voltage
Work in poorly lit areas with the Large white LED backlit display
True-rms voltage and current for accurate measurements on non-linear loads
Measures 10 A directly (20 A overload for 30-seconds) without a current clamp
Resistance, continuity, frequency and capacitance
Record signal fluctuations using Min/Max/Average and elapsed time stamps
Easy to use with one hand
Hands free operation with optional magnetic hanger (ToolPak™)
CAT III 600 V safety rated
Specifications:
Maximum voltage between any terminal and earth ground: 600 V
Surge protection: 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display: 6,000 counts, updates 4 per second
Bar graph: 33 segments, updates 32 per second
Operating Temperature: -10°C to +50°C
Storage Temperature: -40°C to +60°C
Battery type: 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life: 400 hours typical, without backlight
Accuracy Specifications:
DC millivolts:
Range/Resolution: 600.0 mV / 0.1 mV
Accuracy: ±([% of reading] + [counts]): 0.5% + 2
DC volts:
Range/Resolution: 6.000 V / 0.001 V, 60.00 V / 0.01 V & 600.00 V / 0.1 V
Accuracy: ±([% of reading] + [counts]): 0.5% + 2
Auto volts:
Range: 600.0 V / 0.1 V
Accuracy:
2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMS:
Range: 600.0 mV / 0.1 mV
Accuracy:
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS:
Range/Resolution: 6.000 V / 0.001 V, 60.00 V / 0.01 V & 600.0 V / 0.1 V
Accuracy:
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity:
Range: 600 Ω / 1 Ω
Accuracy: Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms:
Range/Resolution: 600.0 Ω / 0.1 Ω, 6.000 kΩ / 0.001 kΩ, 60.00 kΩ / 0.01 kΩ, 600.0 kΩ / 0.1 kΩ & 6.000 MΩ / 0.001 MΩ
Accuracy: 0.9% + 1
Range/Resolution: 40.00 MΩ / 0.01 MΩ
Accuracy: 1.5% + 2
Diode Test:
Range/Resolution: 2.000 V / 0.001 V
Accuracy: 0.9% + 2
Capacitance:
Range/Resolution: 1000 nF / 1 nF, 10.00 μF / 0.01 μF, 100.0 μF / 0.1 μF, 9999 μF / 1 μF & 100 μF to 1000 μF
Accuracy: 1.9% + 2
Range/Resolution: > 1000 μF
Accuracy: 5% + 20%
LoZ capacitance:
Range: 1 nF to 500 μF
Accuracy: 10% + 2 typical
Temperature2 (Type-K thermocouple):
Range/Resolution: -40°C to 400°C / 0.1°C
Accuracy2: 1% + 10
Range/Resolution: -40°F to 752°F / 0.2°F
Accuracy2: 1% + 18
AC μamps true-rms (45 Hz to 500 Hz):
Range/Resolution: 600.0 μA / 0.1 μA
Accuracy: 1.0% + 2
DC μamps:
Range/Resolution: 600.0 μA / 0.1 μA
Accuracy: 1.0% + 2
Hz (V or A input)2:
Range/Resolution: 99.99 Hz / 0.01 Hz, 999.99 Hz / 0.1 Hz, 9.999 Hz / 0.001 Hz & 50.00 Hz / 0.01 Hz
Accuracy: 0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
• Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
• Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical and General Specifications:
Size: 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight: 550 g
Warranty: 3 years
Fluke 62 MAX+ Infrared Thermometer
The Fluke 62 MAX+ infrared thermometer is everything you’d want in your toolbox.
Small in size, extremely accurate and yet easy to use. IP54 rated for dust and water resistance.
Precise yet rugged enough to take a 3-meter drop.
Measure -30 °C to 650 °C (-22 °F to 1202 °F)
Extremely accurate: up to +1.0 °C or + 1.0% of reaching (Fluke 62 MAX+)
IP54 rating for water resistance and dust proof allow you to
work rain or shine and even in the most dirty or dusty industrial sites
Strong enough to withstand a 3m drop. No worry even if you work from a ladder
Small and lightweight; clips to your tool belt or belt loop or easily fits into your tool box
Dual lasers: The 62 MAX+ has dual lasers to help you identify area to be measured
Specifications:
Temperature range: -30°C to 650°C (-22°F to 1202°F)
Accuracy:
±1.0°C or ±1.0% of reading, whichever is greater
-10°C to 0°C: ±2.0
-30°C to -10°C: ±3.0
Response time (95%):
< 300 ms (95% of reading)
Spectral response: 8 to 14 microns
Emissivity: 0.10 to 1.00
Optical resolution: 12:1 (calculated at 90% energy)
Display resolution: 0.1°C (0.2°F)
Repeatability of readings: ±0.5% of reading or <±0.5°C (1°F), whichever is greater
Power: AA battery
Battery life: 8 hours with laser and backlight on
Physical Specifications:
Weight: 255 g (8.99 oz)
Size: 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
Operating temperature: 0°C to 50°C (32°F to 122°F)
Storage temperature: -20°C to 60°C (-4°F to 140°F), (without battery)
Operating humidity: 10% to 90% RH non-condensing at 30°C (86°F)
Operating altitude: 2000 meters above mean sea level
Storage altitude: 12,000 meters above mean sea level
IP rating: IP 54 per IEC 60529
Drop test: 3 meters
Vibration and shock: IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC: EN 61326-1:2006 EN 61326-2:2006
Standards and agency approval:
Compliance: EN/IEC 61010-1: 2001
Laser safety: FDA and EN 60825-1 Class II