FLUKE Thermometer, Electrical Tester and Voltage Detector Kit FLUT6-600/62/1ACKIT

¥269

Category:

Description

Description
Take AC voltage, current, and frequency measurements without making contact with the live voltage with T6-600 tester.
The 62 Max + infrared thermometer helps you identify areas to be measured and the 1AC-II voltage tester tests for energized circuits.
Additionally, this kit is ideal for electricians and HVAC/R technicians.
FieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage
Identify areas to be measured and the voltage tester tests for energized circuits
Fluke T6-600 Electrical Tester
Function Requires test leads Range Resolution Accuracy[1]
FieldSense
ac voltage true-rms No 600 V 1 V ±(3% + 3 counts) 45 Hz – 66 Hz[2] [3]
FieldSense
ac current true-rms No 200.0 A 0.1 A ±(3% + 3 counts) 45 Hz – 66 Hz
FieldSense
frequency (Hz) No 1 Hz ±(1% + 2 counts)[3]
Volts ac true-rms Yes 600 V 1 V ±(1.5% + 2 counts) 45 Hz – 66 Hz
Volts dc Yes 600 V 1 V ±(1% + 2 counts)
Resistance Yes 2000 Ω 1 Ω ±(1% + 2 counts)
Safety 600 V CAT III
Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ).
Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F)
with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.
Accuracy[2]: Add 3 % without an external ground connection. External ground connection required
for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
Accuracy[3]: FieldSense is specified from 16 V to 100 % of range.

Calibration 1-year calibration cycle
Dimensions 61.1 x 259.3 x 43.8 mm
Jaw opening 17.8 mm
Weight 0.35 kg (0.78 lb)
Temperature Operating -10 °C to +50 °C (14 °F to 122 °F)
Storage -30 °C to +60 °C (-22 °F to +140 °F)
Altitude Operating 2,000 m (6,562 feet)
Storage 10,000 m (32,808 feet)
Relative Humidity 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
0% to 45%, 40°C to 50 °C (104 °F to 122 °F)
Battery Type and Life 2 x AA (IEC LR6);
360 hours continuous, typical; 200 hours using FieldSense
Temperature coefficient 0.1 x (specified accuracy) / °C for <18°C or >28 °C
(< 64.4 °F or > 82.4 °F)
Safety IEC/EN 61010-1: Pollution Degree 2
Electromagnetic Environment IEC/EN 61326-1: Portable

Reviews

There are no reviews yet.

Be the first to review “FLUKE Thermometer, Electrical Tester and Voltage Detector Kit FLUT6-600/62/1ACKIT”

Your email address will not be published. Required fields are marked *