Description
ANGLE MEASUREMENT
Accuracy1 Hz and V Absolute, continuous, quadruple: 0.5” (0.15 mgon) or 1” (0.3 mgon)
DISTANCE MEASUREMENT
Range2
Prism (GPR1, GPH1P) 3: 0.9 m to 3,500 m
Non-Prism / Any surface 4: 0.9 m to >1,000 m
Accuracy / Measurement time
Single (prism) 2,5: 0.6 mm + 1 ppm / typ. 2.4 s
Single (any surface) 2,4,5,6: 2 mm + 2 ppm / typ. 2 s 9
Laser dot size At 50m: 8mm x 20mm
Measurement technology System analyser: Coaxial, visible red laser
IMAGING (Overview and Telescope Camera)
Sensor 5 megapixel CMOS sensor
Field of view (overview / telescope) 19.4° / 1.5°
Frame rate Up to 20 frames per second
MOTORISATION
Direct drives based on Piezo technology Rotation speed / Time to change face:
Maximum 200 gon (180°) per s / typically 2.9 s
AUTOMATIC AIMING – LONG RANGE ATRplus
Target aiming range 2
Circular prism (GPR1, GPH1P): 3,000m
360° prism (GRZ4, GRZ122): 1,500 m
Accuracy 1,2 / Measurement time ATRplus angle accuracy Hz, V: 0.5” (0.15 mgon) or 1” (0.3 mgon) / typically 3-4 s
GENERAL
Operating System / Field Software Windows EC7 / Leica Captivate with apps
Processor TI OMAP4430 1GHz Dual-core ARM® Cortex™- A9 MPCore™
Autofocus8 telescope Magnification / Focus Range: 30 x / 1.7m to infinity
Display and keyboard 5‘‘ (inch), WVGA, colour, touch, Face 1 standard, Face 2 optional | 37 keys, illumination
Operation 3x endless drives, 1x Servofocus drive, 2x Autofocus keys 8, user-definable SmartKey
Power management Exchangeable Lithium-Ion battery with internal charging capability
Operating Time up to 9 h
Data storage Internal memory: 2 GB
Memory card: SD card 1 GB or 8 GB
Interfaces RS232, USB, Bluetooth®, WLAN
Weight (Total station including battery) 7.2 kg
Environmental specifications Working temperature range: –20°C to +50°C
Dust & Water (IEC 60529) / Blowing rain: IP65 / MIL-STD-810G, Method 506.5-I
Humidity: 95%, non-condensing
1. Standard deviation ISO 17123-3
2. Overcast, no haze, visibility about 40 km, no heat shimmer
3. 0.9 m to 2,000 m for 360° prisms (GRZ4, GRZ122)
4. Object in shade, sky overcast, Kodak Gray Card (90% reflective)
5. Standard deviation ISO 17123-4
6. Distance > 500 m: Accuracy 4 mm + 2 ppm, Measurement Time typ. 6 s
7. Available on TM60 I models
8. Autofocus for TM60 I models, Servofocus only for TM60 models
9. Up to 50 m, max. measurement time 15 s for full range