FLUKE a3000 FC Wireless AC Clamp Kit FLUFLKA3000FCKIT

¥416

Category:

Description

Description
Connect the a3000 FC Wireless AC Current Clamp Module to your test point, and view the results up to 20 meters
away on the 3000 FC Wireless Digital Multimeter. You’ll save time, with less run-around collecting multiple measurements.
Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine
with other Fluke Connect™ modules as a system for multiple measurements. From short distances,
you can even view readings from modules through closed electrical panels.
Plus no more writing down data as the FC Wireless AC Current Clamp Module captures up to 65,000 sets of time
stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer
increased safety by letting you view readings in a separate location from the test point.
The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect® app has all
the essentials for convenient test and measurement troubleshooting:
AC and DC voltage measurements to 1000V
AC and DC current with 0.01 mA resolution
Continuity, resistance, diode test, capacitance and frequency measurements
MIN/MAX recording
CAT III 1000 V, Cat IV 600 V; IP54
The Fluke a3000 FC Wireless AC Current Clamp Module has all
the essentials for convenient test and measurement troubleshooting:
True-RMS AC clamp meter
Measure up to 400 A AC
Use as a standalone meter or as part of the system
Logging function for recording and saving up to 65,000 readings
Inrush function
Specifications:
Fluke 3000 FC Series Wireless Multimeter

AC Voltage Range / Resolution:
600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
AC Voltage Accuracy:
45 Hz to 500 Hz 1.0% + 3
500 Hz to 1 kHz 2.0% + 3
mV Range / Resolution: 600.0 mV / 0.1 mV
mV Accuracy: 0.09% + 2
V Range / Resolution:
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
V Accuracy:
0.09% + 2
0.15% + 2
Range / Resolution: 600 Ω / 1 Ω
Accuracy: Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω Range / Resolution:
600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Ω Accuracy:
0.5% + 2
0.5% + 1
1.5% + 3
Diode test Range / Resolution: 2.000 V / 0.001 V
Diode test Accuracy: 1% + 2
µF Range / Resolution:
1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF
µF Accuracy:
1.2% + 2
10% typical
mA AC (45 Hz to 1 kHz) Range / Resolution:
60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA
mA AC (45 Hz to 1 kHz) Accuracy: 1.5% + 3
mA DC Range / Resolution:
60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA
mA DC Accuracy: 0.5% + 3
Frequency Range / Resolution:
99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Frequency Accuracy: 0.1% + 1
mA Function Overload protection: Fused, 44/100 A, 1000 V FAST Fuse
mA Function Overload: 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy DC functions: The specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration.
MIN/MAX Recording Accuracy AC functions: The specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration.
Maximum voltage between any terminal and earth ground: 1000 V DC or AC RMS
Ω fuse protection from A inputs:0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD):Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery type: 3 x AA Alkaline batteries, NEDA 15A IEC LR6
Battery life: 250 hours minimum
RF communications: 2.4 GHZ ISM Band
RF communication range:
Open air, unobstructed: Up to 20m
Obstructed, sheetrock wall: Up to 6.5m
Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
Operating Temperature: -10°C to 50°C
Storage Temperature: -40°C to 60°C
Temperature coefficient: 0.1 X (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity:
0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
Operating Altitude: 2,000 m
Storage Altitude: 12,000 m
Electromagnetic compatibility – EMI, RFI, EMC, RF
EN 61326–1:2006, EN 61326–2–2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE
Safety compliance:
ANSI / ISA 61010–1 / (82.02.01): 3rd edition
CAN / CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010–1: 3rd edition
IEC / EN 61010–1:2010
Certifications: CSA, FCC, CE
Ingress Protection (IP) rating: IP54
Pollution Degree: 2
Dimensions (L x W x H): 207mm x 93mm x 47.5mm
Weight: 0.34kg
Fluke a3000 FC Wireless AC Current Clamp Module

Range: 0.5 A to 400.0 A
Resolution: 0.1 A
400.0 A Accuracy:
2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (100 Hz to 500 Hz)
Inrush Max displayed reading: 999.9A
Crest factor (50 Hz / 60 Hz):
3 at 500 A (add 2% for C.F. > 2)
2.5 at 600 A (add 2% for C.F. > 2)
1.42 at 1000 A (add 2% for C.F. > 2)
LCD w/ backlight: 3½ digits
Log rate/interval: 1 sec minimum/adjustable by PC
Battery type: 2 x AA, NEDA 15 A, IEC LR6
Battery life: 400 hours
Memory: Record up to 65,000 readings
RF communications: 2.4 GHZ ISM Band
RF communication range:
Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Operating temperature: -10°C to +50°C
Storage temperature: -40°C to +60°C
Temperature coefficient: Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)

Operating humidity:
90% at 35°C
75% at 40°C
45% at 50°C
Operating Altitude: 2,000 m
Storage Altitude: 12,000 m
EMC: EN 61326-1:2006
Safety compliance: IEC 61010-1, 600 V CAT III, 3rd edition Pollution Degree 2
Safety rating: CAT III 600 V
Certifications: CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating: IP30
Pollution Degree: 2
Jaw opening: 34 mm (1.33 in)
Dimensions (L x W x H): 35.5mm x 74.9mm x 203mm
Weight: 0.22kg

Reviews

There are no reviews yet.

Be the first to review “FLUKE a3000 FC Wireless AC Clamp Kit FLUFLKA3000FCKIT”

Your email address will not be published. Required fields are marked *